mirror of
https://git.kernel.org/pub/scm/linux/kernel/git/stable/linux.git
synced 2026-06-11 15:46:40 +02:00
d674752564
These sensors can accept 2 supplies - one for the sensor and one for IR LED [1]. Add supply properties for the sensor - 2 for the sensors and one external, for their open drain interrupt line, to ensure the sensor is powered on before proceeding with setup. [1] https://www.vishay.com/docs/84274/vcnl4040.pdf Reviewed-by: David Lechner <dlechner@baylibre.com> Signed-off-by: Erikas Bitovtas <xerikasxx@gmail.com> Reviewed-by: Krzysztof Kozlowski <krzysztof.kozlowski@oss.qualcomm.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>