Petre Rodan 91557f3459 iio: pressure: mprls0025pa: fix pressure calculation
[ Upstream commit d63403d4e3 ]

A sign change is needed for proper calculation of the pressure.

This is a minor fix since it only affects users that might have custom
silicon from Honeywell that has honeywell,pmin-pascal != 0.

Also due to the fact that raw pressure values can not be lower
than output_min (400k-3.3M) there is no need to calculate a decimal for
the offset.

Fixes: 713337d914 ("iio: pressure: Honeywell mprls0025pa pressure sensor")