machine_constraints_voltage() currently applies apply_uV against the
machine-supplied [min_uV, max_uV] range, and only afterwards clamps
that range down to what the regulator can actually supply (via
ops->list_voltage()).
If the machine-supplied range is wider than the regulator's actual
range, apply_uV's rounding can pick a selector outside the (correct)
clamped range, so the regulator ends up programmed outside its clamped
min/max. At bring-up this shows up as a voltage read-back outside the
clamped range.
Fix this by moving the clamping block ahead of the apply_uV block, so
apply_uV always targets an already-clamped range. Whether apply_uV
should run is decided from the unclamped constraints beforehand and
stored in a local bool, since clamping must not itself change whether
apply_uV fires.
No functional change to the clamping logic itself, only its position
relative to apply_uV. Its early return 0 exits become fallthroughs
since the apply_uV logic now follows it.
Assisted-by: Claude:claude-sonnet-5
Signed-off-by: Kamal Wadhwa <kamal.wadhwa@oss.qualcomm.com>
Link: https://patch.msgid.link/20260720-b4-regulator-core-clamp-voltage-v1-1-8e5eec076a8e@oss.qualcomm.com
Signed-off-by: Mark Brown <broonie@kernel.org>