e47685ec4c
[ Upstream commit72d6b2459d] If state->duty_cycle is 0x100000000000000, the previous calculation of duty_scale overflows and yields a duty cycle ratio of 0% instead of 100%. Fix this by clamping the requested duty cycle to the maximal possible duty cycle first. This way it is possible to use a native integer division instead of a (depending on the architecture) more expensive 64bit division. With this change in place duty_scale cannot be bigger than 256 which allows to simplify the calculation of duty_val. Fixes:6f0841a819("pwm: Add support for Azoteq IQS620A PWM generator") Tested-by: Jeff LaBundy <jeff@labundy.com> Signed-off-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de> Signed-off-by: Thierry Reding <thierry.reding@gmail.com> Signed-off-by: Sasha Levin <sashal@kernel.org>