commit4373cfa38eupstream. In is_full_charged(), power_supply_get_by_name() is called to obtain a reference to the fuel_gauge power supply. If the voltage check (uV >= desc->fullbatt_uV) succeeds, the function returns true directly without releasing the reference, leaking the refcount. Fix this by setting a flag and jumping to the out label where power_supply_put() properly drops the reference. Cc: stable@vger.kernel.org Fixes:e132fc6bb8("power: supply: charger-manager: Make decisions focussed on battery status") Signed-off-by: WenTao Liang <vulab@iscas.ac.cn> Link: https://patch.msgid.link/20260611005322.53096-1-vulab@iscas.ac.cn Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>