arm: dts: mediatek: Add missing cooling device properties for CPUs
[ Upstream commit 0c7f7a5150 ]
The cooling device properties, like "#cooling-cells" and
"dynamic-power-coefficient", should either be present for all the CPUs
of a cluster or none. If these are present only for a subset of CPUs of
a cluster then things will start falling apart as soon as the CPUs are
brought online in a different order. For example, this will happen
because the operating system looks for such properties in the CPU node
it is trying to bring up, so that it can register a cooling device.
Add such missing properties.
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Matthias Brugger <matthias.bgg@gmail.com>
Signed-off-by: Sasha Levin <alexander.levin@microsoft.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
committed by
Greg Kroah-Hartman
parent
65470af8b1
commit
d79cdff572
@@ -92,6 +92,7 @@
|
||||
<&apmixedsys CLK_APMIXED_MAINPLL>;
|
||||
clock-names = "cpu", "intermediate";
|
||||
operating-points-v2 = <&cpu_opp_table>;
|
||||
#cooling-cells = <2>;
|
||||
clock-frequency = <1300000000>;
|
||||
};
|
||||
|
||||
@@ -103,6 +104,7 @@
|
||||
<&apmixedsys CLK_APMIXED_MAINPLL>;
|
||||
clock-names = "cpu", "intermediate";
|
||||
operating-points-v2 = <&cpu_opp_table>;
|
||||
#cooling-cells = <2>;
|
||||
clock-frequency = <1300000000>;
|
||||
};
|
||||
|
||||
@@ -114,6 +116,7 @@
|
||||
<&apmixedsys CLK_APMIXED_MAINPLL>;
|
||||
clock-names = "cpu", "intermediate";
|
||||
operating-points-v2 = <&cpu_opp_table>;
|
||||
#cooling-cells = <2>;
|
||||
clock-frequency = <1300000000>;
|
||||
};
|
||||
};
|
||||
|
||||