Akinobu Mita 73e3e3fc50 iio: adc: ti-ads1015: avoid getting stale result after runtime resume
This driver assumes that the device is operating in the continuous
conversion mode which performs the conversion continuously.  So this driver
doesn't insert a wait time before reading the conversion register if the
configuration is not changed from a previous request.

This assumption is broken if the device is runtime suspended and entered
a power-down state.  The forthcoming request causes reading a stale result
from the conversion register as the device is runtime resumed just before.

Fix it by adding a flag to detect that condition and insert a necessary
wait time.

Cc: Daniel Baluta <daniel.baluta@gmail.com>
Signed-off-by: Akinobu Mita <akinobu.mita@gmail.com>
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2017-08-20 15:41:13 +01:00
2017-07-23 08:13:11 +02:00
2017-08-09 14:31:58 +01:00
…
…
2017-07-23 16:15:17 -07:00

Linux kernel
============

This file was moved to Documentation/admin-guide/README.rst

Please notice that there are several guides for kernel developers and users.
These guides can be rendered in a number of formats, like HTML and PDF.

In order to build the documentation, use ``make htmldocs`` or
``make pdfdocs``.

There are various text files in the Documentation/ subdirectory,
several of them using the Restructured Text markup notation.
See Documentation/00-INDEX for a list of what is contained in each file.

Please read the Documentation/process/changes.rst file, as it contains the
requirements for building and running the kernel, and information about
the problems which may result by upgrading your kernel.
S
Description
No description provided
Readme
5.7 GiB
Languages
C 96.9%
Assembly 0.9%
Rust 0.6%
Shell 0.6%
Python 0.5%
Other 0.3%