Daniel Lezcano fc656fa14d thermal/drivers/netlink: Add the temperature when crossing a trip point
The slope of the temperature increase or decrease can be high and when
the temperature crosses the trip point, there could be a significant
difference between the trip temperature and the measured temperatures.

That forces the userspace to read the temperature back right after
receiving a trip violation notification.

In order to be efficient, give the temperature which resulted in the
trip violation.

Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Acked-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Acked-by: Rafael J. Wysocki <rafael@kernel.org>
Link: https://lore.kernel.org/r/20211001223323.1836640-1-daniel.lezcano@linaro.org
2021-10-07 15:41:38 +02:00